Anthony Liftgates don't break often, but even the most rugged parts don't last forever. Damage or normal wear and tear can interfere with normal liftgate operation. We've prepared this section to help guide you step-by-step through the most common troubleshooting procedures for liftgate repair. Simply locate and click the description that most closely matches your issue, then follow the troubleshooting steps outlined on that page.

<< Return to Troubleshooting Guide

Platform will not close at all, motor does run.  

Possible Cause #1 Bad cartridge valve coil.
Action -

Remove coil from cartridge and test magnetism of inside of soil with metal object (i.e. screwdriver) while energizing 'down' control side of switch only.

(Diagnosis time - 15 minutes / Repair time - 30 minutes).

Part Numbers - A-176306 - Coil
Possible Cause #2 Closer valve stuck in the closed position.
Action - With platform on the ground, remove closing valve, clean and inspect. If plunger not moving freely, replace valve.

(Diagnosis time - 15 minutes / Repair time - 30 minutes).
Part Numbers - A-176304 - Closer valve
Warranty Information:
Base Warranty:

3 Years on mechanical structure.

2 Years on hydraulic & electrical components.

Warranties are void if genuine Anthony parts are not used.

 

FOR ANTHONY LIFTGATES ASSISTANCE CALL (800) 482-0003